Laserfiche WebLink
<br />Section 2515 (f) Plywood Roof Sheathing. Shall be amended <br /> <br />so as to require all plywood, where used as structural roof sheathing, to <br /> <br />be a minimum thickness of one-half inch (1/2") or greater if required in <br /> <br /> <br />Table No. 25-0. <br /> <br /> <br />Section 2507 (f) 3. Plywood. Where plywood is used for <br /> <br />covering the exterior of outside walls, it shall be of the exterior type <br /> <br />weatherboarding not less than one-half inch (1/2") thick. <br /> <br />Section 2806 (a) Footings - General. Shall be amended so <br /> <br />as to require frost wall footings to be at least three feet and six inches <br /> <br />(316") below the finished grade adjacent to the wall at all points. <br /> <br />Section 1405 (b) Room Sizes and Ceiling Heights. This <br /> <br />section shall be amended so as to conform to Section 2 5.020 of the <br /> <br />Village Code. <br />Chapter 51. Heat Producing Appliances. The provisions of <br /> <br />Chapter 51 shall be in addition to rather than in lieu of provisions now <br /> <br /> <br />enacted in the applicable provisions of the Village Code (heating code). <br /> <br /> <br />Section 5101 (d) Installation. Appliances shall be installed <br /> <br /> <br />not less than eighteen inches (18") above the floor. <br /> <br />Section 2305 Roof Loads. Add to Table 23-B Roof Live Loads <br /> <br />per Square Foot to read as follows: <br /> <br />However in no instance shall ordinary roofs, either flat or <br /> <br />pitched, be designed for a load less than forty (40) pounds per square <br /> <br />foot of horizontal projection in addition to the dead load, and in addition <br /> <br />to either the wind or other loads. <br /> <br />-3- <br />