My WebLink
|
Help
|
About
|
Sign Out
Home
2005_0822_Packet
Roseville
>
City Council
>
City Council Meeting Packets
>
2005
>
2005_0822_Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/9/2014 9:16:46 AM
Creation date
9/14/2009 10:04:07 AM
Metadata
Fields
Template:
Roseville City Council
Document Type
Council Agenda/Packets
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
394
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. � . . . ___. _.L' _..' _" _'___'_____.. <br />�r��� � F;� r �I��e� ]?�F,��T -1 1 <br />�3�tf1 y � F i.�'i�l <br />. . _, �}�. ; ¢�.�:: <br />9. When required by the local f�'e chief, multiple AST installations shall be protected by an <br />approved fire protection system. <br />Additional requirements for 2-HOUR PROTECTED AST <br />Fire resistive 2-hour protected above ground storage tanks usually include steel tanks that are double <br />wall and encased in some form of protective insulation such as reinforced concrete. These tanks are <br />constructed to be fire resistive and thus have reduced requirements for separation between the tank <br />and buildings and also between the tank and dispenser. A plain steel tank (either single or double <br />wall) is not a 2-hour protected tank and must instead be installed following the spacing requirements <br />for UL 142 or UL 921 tanks found on page 4 of this information sheet. <br />This page covers the additional requirements for double wall fire resistive <br />2-hour protected tanks. The separation distances given here apply only to this <br />type of tank and do not apply for single or double wall plain steel tanks. <br />ASTs shall not exceed 12,000 gallons individual capacity or 48,000 gallons aggregate capacity at <br />any one dispensing site. <br />2. ASTs 1'ess than or equal to 6,000 gallons shall be located at least 15 feet from property lines that <br />can be built upon, including opposite sides of a public way. These ASTs shall also be located at <br />least 5 feet from buildings and the near side of a public way (see the table below) <br />3. ASTs greater than 6,000 gallons shall be located at least 25 feet from property lines that can be <br />built upon, including opposite sides of a public way. These ASTs shall also be located at least 15 <br />feet from buildings and the near side of a public way (see the table at the bottom of this page). <br />4. ASTs shall have overfill prevention that will provide notification at 85% fill and automatically <br />stop fuel flow at 90%. <br />5. Dispensing devices can be installed on or adjacent to the AST. <br />6. Antisiphon devices shall be installed on the external piping when the piping extends below the <br />liquid level of the AST. <br />7. Fill openings shall have a spill container at least 5 gallon capacity. <br />Minimum separation requirements for protected abovcground tanks <br />lndividual "1'ank <br />Capacity <br />(gallons) <br />Less than or equal <br />to 6,000 <br />Greater than 6,000 <br />Minimum distance from <br />properly linewhich is or <br />can be built upon, <br />including the opposite <br />side of a public way <br />15 feet <br />25 feet <br />Minimum distance � <br />from the nearest side of I <br />any public way or from � <br />the nearest important <br />building on the same i <br />5 feet <br />15 feet .. . _ <br />Minimum I <br />distance i <br />between tanks <br />I <br />! 3 feet <br />3 feet <br />� <br />,�� <br />
The URL can be used to link to this page
Your browser does not support the video tag.