My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
09-09-2020 PC
ArdenHills
>
Administration
>
Commissions, Committees, and Boards
>
Planning Commission
>
Planning Commission Packets
>
2020
>
09-09-2020 PC
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/9/2020 2:51:25 PM
Creation date
9/9/2020 2:49:47 PM
Metadata
Fields
Template:
General
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
93
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
____________________________________________________________________________________________ <br />City of Arden Hills <br />Planning Commission Meeting for September 9, 2020 <br />P:\Planning\Planning Cases\2020\20-010 4200 Round Lake Road PP/FP/CUP/PUD\PC Packets <br />Page 6 of 13 <br />E. Parking Setbacks - Flexibility Requested <br />The GB district requires a 50 foot setback for parking areas from public streets and ROW. The <br />applicant was requesting a 30 foot parking lot setback from Gateway Boulevard ROW and due to <br />the required ROW dedication the Applicant is now requesting a 20 foot setback to the parking area <br />on the north side of the subject parcel. According to the Site Plan the proposed parking areas are <br />located approximately 50 feet from the back of curb of Gateway Boulevard. However, several <br />properties along Round Lake Road and Gateway Boulevard have similar or greater reduction in <br />parking lot setbacks. <br />F. Building Height β Flexibility Requested <br />Section 1305.04 of the City Code defines building height as βthe vertical distance from the average <br />elevation of the grade along a face of a building to the highest point of the roof surface of flat <br />roofs, the deck line of mansard roofs, or the average height between the eaves and the highest ridge <br />of gable, hip, or gambrel roofs.β These measurements are illustrated in the drawing below. <br />Maximum height in the GB district is 35 feet. The Applicant is proposing a facility with maximum <br />interior clear height of 32 feet. As it directly relates to the interior clear height, the proposed <br />maximum building height measured from the finished floor elevation is 40 feet. However, special <br />requirements for the GB district state that in order to accomplish the intensity and scale of <br />development consistent with the defined purpose of the GB District, multi-story buildings will be <br />encouraged. <br />6. General District Provisions <br />A. Parking and Site Operations β Meets Requirements <br />The proposed Site Plan shows three (3) accesses onto Gateway Boulevard. The proposed access <br />can be classified as employee and loading driveway accesses. The employee accesses shown on <br />the next page are 24 feet wide and the loading driveway access is 35.6 feet wide. The loading <br />access will provide access to the 38 dock doors located on the north side of the building. The <br />eastern employee access is located on Lot 2. This proposed access will be a shared access driveway <br />for both Lot 1 and Lot 2 when it develops. This will require a cross access and maintenance <br />agreement between the two parcels which will be further addressed in the Development Agreement <br />related to the Project.
The URL can be used to link to this page
Your browser does not support the video tag.