<br />City of Arden Hills, MN – 25X.137753 LIFT STATION CONTROL SYSTEM <br />January 2026 PAGE 26 90 04-25 <br />©2026 Design Tree Engineering, Inc All Rights Reserved <br /> EXISTING SCADA SYSTEM MODIFICATIONS <br />A. Provide all programming, wiring, and hardware modifications to transmit, receive, display, trend, <br />report, alarm, and handle the data between the lift stations and the SCADA Master. <br />B. Programming shall be done in a manner consistent with the existing programming and shall include but <br />not be limited to <br />1. Master radio. <br />2. Master PLC. <br />3. Human Machine Interface Software. <br />4. Software Alarm dialer. <br />C. Alarm dialer shall be modified as required to incorporate the new alarms in similar fashion to existing <br />lift station alarms. <br />D. Screens/Reports <br />1. Addition of new Lift Stations to existing map screen. <br />2. Modify existing lift station screens to incorporate new monitoring points, alarms and setpoints. <br />3. Add alarms to SCADA PC alarm dialing software. <br /> SYSTEM TESTING <br />A. All components of the system shall be thoroughly simulated and testing in the control supplier’s facility <br />prior to shipment. <br />1. Contractor shall provide testing approval certification from the panel manufacturer prior to <br />receiving shipment. <br />B. On Site Testing: <br />1. Verify that each instrumentation and control device is wired and operating correctly. Owner <br />control system programmer will provide "online" PLC testing of each field device, and coordinate <br />with Contractor the proper operation of each instrumentation and control device. <br />2. Provide services of a factory-trained person to checkout, test, and commission the system on Site. <br />3. Place equipment into service and provide operation as specified. <br />4. Provide actual activation of each control function and alarm in the system. If actual activation is not <br />possible, the function shall be simulated. <br />5. Record all Changes in the Control Systems <br />a. Revise all wiring diagrams and schematic diagrams to show final installation. <br />b. Insert revised diagrams into each operation and maintenance manual in place of original <br />diagrams. <br /> SYSTEM COMMISSIONING & DEMONSTRATION <br />A. Upon completion of Contractor’s acceptance checks, settings, and tests, the Contractor shall <br />demonstrate that the equipment is in good operating condition and properly performing the intended <br />function. <br />B. Process Engineer will witness operational tests and instruct programmer to adjust setpoints to achieve <br />the operation desired by the Process Engineer. <br />C. Contractor shall have system programmer at site for the commissioning process. <br />D. A minimum of 2-week notice will be provided to the Contractor for scheduling of commissioning dates.
The URL can be used to link to this page
Your browser does not support the video tag.