My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
CCP 01-21-2003
ArdenHills
>
Administration
>
City Council
>
City Council Packets
>
2000-2009
>
2003
>
CCP 01-21-2003
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/8/2007 1:18:07 PM
Creation date
11/14/2006 2:33:55 PM
Metadata
Fields
Template:
General (2)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
98
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />1 <br />I. <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />-- <br />I <br />I <br />I <br />I <br />I <br />I <br />I. <br />I <br />I <br /> <br />Roadways <br /> <br />One public road, Femwood Avenue, currently bisects the campus (see Figure 3). <br />Femwood Avenue serves the AUAR study area buildings as well as the businesses just <br />north of the study area along Guidant Drive North. The other main roadway on the site is <br />Guidant Drive North. Although this is a private roadway owned by Guidant, the roadway <br />is also used by businesses to the north to gain access to and from Lexington Avenue. The <br />concept plan for Phase I (see Table l) of the Master Plan proposes to convert Guidant <br />Drive North to a public roadway and ultimately vacate Fernwood Avenue to provide safer <br />movement of employees through the proposed campus. Although these roadway <br />improvements are included in the Master Plan concept that is currently being developed for <br />the site, the improvements have not been approved by the City. Refer to Items 21 and 25.C <br />for more details. <br /> <br />Sanitarv Sewer <br /> <br />The study area is currently served by city sanitary sewer. Three lines serve the campus and <br />are located in CR F, Hamline Avenue and in Fernwood Avenue. The City of Arden Hills <br />has confirmed that the existing sanitary sewer main lines have adequate capacity to serve <br />the proposed development. Lateral line extensions will be made, as needed, to the existing <br />sanitary sewer main line in Fernwood Avenue to serve the new buildings. Refer to <br />Item 18 for more details. <br /> <br />Water Supply <br /> <br />Existing water mains are located in CR F, Hamline Avenue and in Fernwood Avenue. The <br />City of Arden Hills has confirmed that the existing water mains have adequate capacity to <br />serve the proposed development. Connections from the existing water lines in Femwood <br />A venue to the new buildings will be required and added as needed. Refer to Item 13 for <br />more details. <br /> <br />Storm Water <br /> <br />Storm water runoff from the existing site condition discharges directly into the wetlands on <br />and adjacent to the campus. The campus expansion will provide for treatment prior to <br />storm water entering the wetlands by methods of infiltration, retention and NURP ponds in <br />accordance with the City of Arden Hills and Rice Creek Watershed District requirements. <br />The overall storm water runoff volumes will decrease from existing conditions as the <br />proposed campus expansion will decrease the amount of impervious surface area. Refer to <br />Item 17 for more details. <br /> <br />7. PROJECT MAGNITUDE DATA <br /> <br />AUAR: <br />The cumulative totals of the parameters called for should be given for each major <br />development scenario, except that inFormation on "manufacturing," "other industrial, " <br />"institutional," "agricultural," and "building heights" is optional. <br /> <br />TOTAL PROJECT AREA (ACRES): 92.7 OR LENGTH (MILES) NA <br /> <br />Guidant Campus Master Plan <br />final AUAR and Mitigation Plan <br /> <br />- 6- <br /> <br />January 2003 <br />
The URL can be used to link to this page
Your browser does not support the video tag.