My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2017-02-07 P & Z Handouts
Centerville
>
Planning & Zoning
>
Agenda Packets
>
1994-2022
>
2017
>
2017-02-07 P & Z Handouts
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/17/2018 2:54:59 PM
Creation date
1/17/2018 2:54:09 PM
Metadata
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
(3 Stantec <br /> February 2,2017 <br /> Mike Ericson <br /> Page 2 of 5 <br /> Reference: Rte age Johnson CUP <br /> c. Side: Future development on the west side of the site must meet the required 20' <br /> setback, <br /> d. Rear:30' required, 130' provided <br /> 4) Parking:5 spaces per 1,000 sq ft of office area,2 spaces per 1,000 sq ft of industrial space. <br /> Parking calculations submitted on the Site Plan are correct and adequate: 60 required, 52 <br /> spaces provided plus 8 proof-of-parking spaces. <br /> 5) Building Height:35' maAmum;34' proposed. <br /> 6) Landscaping: <br /> a. 10%of the site area must be green!ipuL;tj,- this must be verified-areas are not <br /> provided on the site plan, but rough measurements indicate this standard is met. <br /> b. 3%oft surface area parking area must be landscaped with grass,shrubbery, or <br /> ground cover; must be verified-areas are not provided on the site plan, but rough <br /> measurements indicate this standard is met. <br /> c. Overstory trees are required at a rate of one tree per 3,000 sq ft of site area, the <br /> numbers and calculations on the landscape plan meet this standard. <br /> d. Shrubs and foundation plants are required at a rate of one planting per 10 lineal feet <br /> of building perimeter and parking lot perimeter;the numbers and calculations on the <br /> landscape plan meets this standard. <br /> 7) Outdoor storage is permitted if necessary fora permitted commercial use, is is the case <br /> here.The ordinance limits the size oft e outdoor storage area to a maAmum of 1.5 to one <br /> ratio of storage area to building footprint.Site Plan Al.I has a table with a not indicating <br /> that it was revised on January 2 ,2017.This table labeled Site Information lists the building <br /> footprint as 19,368 sq. ft. <br /> The table also lists the Outdoor Storage as 19,368 X 1.5=29,052 sq. ft.The outdoor storage <br /> area shown on the site plan appears to be significantly larger than 29,052 sq.ft. It is unclear if <br /> the intent is to limit the size of the outdoor storage area to 29,052 sq. ft. <br /> If the proposed outdoor storage area is to be greater than 29,052 sq. ft. the applicant will <br /> need to demonstrate a practical difficulty and apply for a variance, or commit to <br /> constructing a larger building. Additional screening and landscaping could also be required <br /> as conditions of the CUP if a need is determined based on the final plans.The applicant <br /> should be prepared to make their intentions clear at the meeting. <br /> 8) Screening requirements are to be reviewed in the site plan process.The perimeter oft site <br /> has an 8' high security fence,with dense landscaping on the sides and rear,and overstory <br /> boulevard trees in front.The screening and landscaping is acceptable provided a <br /> satisfactory guarantee of survival of the plant materials is provided and no additional <br /> Design with community In mind <br /> me c,\users\merieson\appdata\local\mlcr=ff\vvindtempomry Internet files\conient.oullook\rkks0eq4\ruffddge johnson plan reVnw-2017 .d <br />
The URL can be used to link to this page
Your browser does not support the video tag.