Laserfiche WebLink
RISER PLATES shall be used between adjacent decks of 12" rise or greater. Riser plates shall be constructed of 11 ga. A-60 Galvannealed. <br />The step rung and supports (on 24” models and certain 18” models) shall be constructed of 1" tube, solid welded. The risers shall bolt to the edge <br />of the upper and lower decks. Kids’ Choice 18” and 24” riser assemblies shall feature an arch enclosure assembly comprising top supports, a bottom <br />support, and an arched upright constructed of 1" pipe, formed, mashed, and punched, with infill vertical rungs of 3/4" x 1" oval tube. For models <br />that have the Nature Arch enclosure, enclosure shall comprise two top supports and arched upright of 1" pipe solid welded. Brackets of 11 ga. <br />galvanized sheet steel are stitch welded to the 1" pipe frame. Boards of 1" x 5.5" recycled plastic and wood composite are fastened to the frame <br />with Fastener Style A hardware. Tots’ Choice 18” and 24” riser assemblies shall feature a loop enclosure comprising two top supports, an arched <br />upright and infill vertical rungs of 1" tube. Kids’ Choice, Tots’ Choice and Tots’ Choice Expansion 6” risers shall be used in conjunction with a 90- <br />degree L-Ramp. Each enclosure assembly shall be solid welded. Models with enclosures shall contain Versalok Fasteners. All models shall <br />contain Fastener Style A hardware. Riser plates, enclosures and clamps shall have a Mira-Cote finish. <br />PLAYCOVER SHADES shall attach to Kids' Choice, Tots' Choice and Tots' Choice Expansion decks to provide shade to play structures. <br />Pyramid and Sail Shade structures are designed to meet the requirements of ASCE 7-05 (IBC 2006, IBC 2009, CBC2010) and ASCE 7-10 (IBC <br />2012). Shades will have alive load of 5 PSF, snow load of 10 PSF, design wind speed of 90 MPH (3-sec gust), exposure C (from ASCE 7-05), and a <br />design wind speed of 115 MPH, risk category II (from ASCE 7-10). All tube shall conform to ASTM A500. Steel plate shall conform to ASTM A572, <br />Fy = 50 KSI. All fabrication and erection of structural steel shall conform with the current edition of AISC “Specification for the Design, Fabrication <br />and Erection of Structural Steel for Buildings”. All fabrication and erection of the light gauge pipes shall conform to AISI cold-formed steel <br />specifications. Steel welds shall conform to AWS D.1: Electrodes, Class E70XX, Low Hydrogen. Frames have primer and 3 mils of powder coat <br />electrostatically applied. Structural Steel Columns are made of 88.9 mm (3.5") O.D. pre-galvanized tubing for PB and are made of 127 mm (5") O.D. <br />pre-galvanized tubing for KB. Structural Steel Rafters are made of 88.9 mm (3.5") O.D. pre-galvanized tubing. Fabric shade cloth has been <br />specifically developed to produce a very strong and stable outdoor fabric for use in tension structures and shade awnings. This range offers the <br />ultimate combination of maximum sun protection plus the strength and durability to ensure maintenance-free, long life performance. Mildew and Rot <br />resistant. Heat and hail resistant. Maintains color in all weather conditions. High Density Polyethylene (HDPE), UV stabilized with a monofilament <br />and lockstitch sewing construction producing a fabric that will not tear or fray if cut. Available in Standard and Fire-Retardant Fabric. 6 Colors in <br />Standard Fabric and 7 Colors in Fire Retardant Fabric. Provides shade factors up to 94% and blocks up to 95% of dangerous UV solar radiation for <br />Standard Fabric. Provides shade factors up to 86% and blocks up to 84% of dangerous UV solar radiation for Fire Retardant Fabric. Temperature <br />reduction of up to 30 degrees. It is recommended to remove Shade fabric prior to snowfall. Structural framing may remain in place during winter <br />months. Hexagon Shade structures are designed to meet the requirements of ASCE 7-05 (IBC 2006, IBC 2009, CBC 2010), ASCE 7-10 (IBC 2012, <br />IBC 2015, IBC 2018, CBC 2013, CBC 2016) and ASCE 7-16 (IBC 2018, CBC 2019). Shades will have a live load of 5 PSF, snow load of 10 PSF, <br />nominal design wind speed of 90 MPH (3-sec gust), exposure C, risk category II (from ASCE 7-05) and ultimate design wind speed of 115 MPH, <br />exposure C, risk category II (from ASCE 7-10 and ASCE 7-16). All tube shall conform to ASTM A500. Steel plate shall conform to ASTM A572, Fy = <br />50 KSI. All fabrication and erection of structural steel shall conform with the current edition of AISC “Specification for the Design, Fabrication and <br />Erection of Structural Steel for Buildings”. All fabrication and erection of the light gauge pipes shall conform to AISI cold-formed steel specifications. <br />Steel welds shall conform to AWS D.1: Electrodes, Class E70XX, Low Hydrogen. Frames have primer and 3 mils of powder coat electrostatically <br />applied. Structural Steel Columns are made of 88.9 mm (3.5") O.D. pre-galvanized tubing for PB and are made of 127 mm (5") O.D. pre-galvanized <br />tubing for KB. Structural Steel Rafters are made of 88.9 mm (3.5") O.D. pre-galvanized tubing. Fabric shade cloth has been specifically developed to <br />produce a very strong and stable outdoor fabric for use in tension structures and shade awnings. This range offers the ultimate combination of <br />maximum sun protection plus the strength and durability to ensure maintenance-free, long life performance. Mildew and Rot resistant. Heat and hail <br />resistant. Maintains color in all weather conditions. High Density Polyethylene (HDPE), UV stabilized with a monofilament and lockstitch sewing <br />construction producing a fabric that will not tear or fray if cut. Available in Standard and Fire Retardant Fabric. 6 Colors in Standard Fabric and 7 <br />Colors in Fire Retardant Fabric. Provides shade factors up to 94% and blocks up to 95% of dangerous UV solar radiation for Standard Fabric. <br />Provides shade factors up to 86% and blocks up to 84% of dangerous UV solar radiation for Fire Retardant Fabric. Temperature reduction of up to <br />30 degrees. It is recommended to remove Shade fabric prior to snowfall. Structural framing may remain in place during winter months. Sail Shades <br />(17 ft. and 26 ft.) are designed to meet to meet the requirements of ASCE 7-05 (IBC 2006, IBC 2009, CBC 2010), ASCE 7-10 (IBC 2012, IBC 2015, <br />IBC 2018, CBC 2013, CBC 2016) and ASCE 7-16 (IBC 2018, CBC 2019). Shades will have a live load of 5 PSF, snow load of 10 PSF, nominal <br />design wind speed of 90 MPH (3-sec gust), exposure C, risk category II (from ASCE 7-05) and ultimate design wind speed of 115 MPH, exposure C, <br />risk category II (from ASCE 7-10 and ASCE 7-16). All tube shall conform to ASTM A500. Steel plate shall conform to ASTM A572, Fy = 50 KSI. All <br />fabrication and erection of structural steel shall conform with the current edition of AISC “Specification for the Design, Fabrication and Erection of <br />Structural Steel for Buildings”. All fabrication and erection of the light gauge pipes shall conform to AISI cold-formed steel specifications. Steel welds <br />shall conform to AWS D.1: Electrodes, Class E70XX, Low Hydrogen. Frames have primer and 3 mils of powder coat electrostatically applied. <br />Structural Steel Columns are made of 88.9 mm (3.5") O.D. pre-galvanized tubing for PB and are made of 127 mm (5") O.D. pre-galvanized tubing for <br />KB. Structural Steel Rafters are made of 88.9 mm (3.5") O.D. pre-galvanized tubing. Fabric shade cloth has been specifically developed to produce <br />a very strong and stable outdoor fabric for use in tension structures and shade awnings. This range offers the ultimate combination of maximum sun <br />protection plus the strength and durability to ensure maintenance-free, long life performance. Mildew and Rot resistant. Heat and hail resistant. <br />Maintains color in all weather conditions. High Density Polyethylene (HDPE), UV stabilized with a monofilament and lockstitch sewing construction <br />producing a fabric that will not tear or fray if cut. Available in Standard and Fire Retardant Fabric. 6 Colors in Standard Fabric and 7 Colors in Fire <br />Retardant Fabric. Provides shade factors up to 94% and blocks up to 95% of dangerous UV solar radiation for Standard Fabric. Provides shade <br />factors up to 86% and blocks up to 84% of dangerous UV solar radiation for Fire Retardant Fabric. Temperature reduction of up to 30 degrees. It is <br />recommended to remove Shade fabric prior to snowfall. Structural framing may remain in place during winter. <br />CHAMELEON II SLIDE SYSTEM shall feature interchangeable bedway sections to present maximum versatility in design configuration. The <br />componentized, open bedway slide assembly may be attached to 2'-6" - 8' decks. The bedway sections, entry panel and exit section shall be <br />constructed of double wall Rockite with a 18" bedway and <br />13-3/4" high sidewalls. The entry panel shall be supported by a rung of 1" pipe. The "T" front leg shall be constructed of 1.5" X 16 ga. square tube <br />and a bracket of 7 ga. galvanized sheet steel. Support legs shall be constructed of 1.66 OD x 13 ga. tube and a mounting bracket of 7 ga. sheet, <br />solid welded. The assembly shall contain Versalok Fasteners and Fastener Style A hardware. The rung, front leg, support legs and leg brackets <br />shall have a Mira-Cote finish. The Rockite slide sections shall have color molded in. <br /> <br />