My WebLink
|
Help
|
About
|
Sign Out
Home
2003_0310_packet
Roseville
>
City Council
>
City Council Meeting Packets
>
2003
>
2003_0310_packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/24/2011 10:52:16 AM
Creation date
10/24/2011 10:43:31 AM
Metadata
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
120
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
5.12 overall, the combination of large units, additional in -house amenities, and housing specifically <br />for seniors, will reduce traffic and use in the neighborhood, making this PUD project more of a <br />medium density development (5 to 12 units per acre) than the characteristics of a higher density <br />active apartment. Given the characteristics of the Presbyterian Homes proposal, the project <br />should reviewed as a medium density residenal project. <br />5.13 The structure is proposed with brick, stucco, concrete (stained) lap siding, precast concrete <br />accent bands, asphalt shingles, alunr.inum soffit and fascia, vinyl windows, aluminum guard rail <br />(decks), and vinyl clad patio doors, <br />5.14 The proposed 4 story structure will be approximately 58 feet ` in height to the top of the roof, <br />with a tower at the southeast corner of the structure extending to a height of approximately 70 <br />feet. The roof is proposed with a 6/12 pitch. The tower has a fiat roof, In the 1 -7 district there <br />is no maximum height limit. <br />5.15 The Code required parking for the site would include 10 spaces for the existing office <br />complex, 12 for the proposed office addition, 70 spaces for the proposed retail area, and 190 for <br />the senior apartments, for a total of 392 on-site parking spaces (no parking has been allocated <br />for the future development). By comparison, with senior housing, the site plan indicates a total <br />of 224 surface parking spaces and 95 underground parking spaces for a total of 316 parking <br />spaces. <br />5.16 The main parking lot for the retail area lies adjacent to Harnfine Avenue and is a one way <br />design with the entrance from the north off of the access drive and an exist on the south to <br />Hamiine Avenue. Parking in this lot is angled on both sides of the lot and includes 40 parking <br />spaces. The main parking lot for the office building will lie to the west of the office and <br />includes 109 parking spaces. Accommodations have been made for shared parking along the <br />access drive from Hamline Avenue on either side of the drive lane, which includes 30 parking <br />spaces. These parking spaces could be used for office or retail patrons. The main parking for <br />the senior apartment residents will be provided underground, which includes 95 parking spaces. <br />Additional visitor and retail parking will be provided on the west side of the structures with a <br />limited number of spaces being provided on the north side of the senior apartment complex. <br />The total parking for these two areas includes 45 parking spaces. Ample lanai adjacent to the <br />proposed north parking lot remains to construct additional parking if needed. A "proof of <br />parking plan" will be included with the final site plan and planned unit development agreement. <br />5.17 Three access points are proposed for the site. The first Iles along Centennial Drive and will be <br />primarily used by the office building. The second access is existing and lies along Hamlinc <br />Avenue and would be primarily used for access to the retail portion of new structure, as well as <br />a secondary access to the office and visitors to the senior apartments. The egress along <br />Hatmline Avenue is due to the one way angled parking along the front side (east) of the retail <br />area. The third access lies along Terrace Drive and will be the primary access for those <br />residents living in the senior apartments, because of its proximity to the underground gage <br />entrance. <br />PF342 I -- RCA Concept Play, - 031003 page 4 of 10 <br />
The URL can be used to link to this page
Your browser does not support the video tag.