<br />Shoreland Ordinance/B-6 Zoning Ordinance SummalY Twin Lakes Mix'ed Use Redevelopment -Roseville, Minnesota
<br />Sanitaty Sewer Capacity/Water Adequacy/Stormwater System/Roadway Capacity February 10,2005
<br />Gpvernment Approvals Schedule/Site Plan Modifications Page 5 0[7
<br />
<br />Sanitary Sewer Capacity
<br />This comparison is based on the anticipated volumes, areas, square footages and units as published in the
<br />May 200 I Alternative Urban Areawide Review (AUAR) versus the presently proposed areas, square .
<br />. footages and units. A ratio has been used to calculate anticipated volumes based on the AUAR figures.
<br />
<br />In computing anticipated sanitary sewer flows, an average of 1,200 square feet per unit was assumed for
<br />townhome (TH) use, while an average of 800 square feet per unit was assumed for condominium /
<br />apartment (CA) use.
<br />
<br />Based on the flow identified in the AUAR,RLK has prepared the following comparison of the anticipated
<br />. sanItary sewer flows for the uses as proposed in the May 2001 AUARand the current Rottlund Proposal
<br />as identified in the following chart.
<br />
<br /> Sanitary Sewer Flows
<br /> Mav 2001 AUAR Rottlund Proposal
<br />P::,.:t: rJ'l. Total Sanitary Total Sanitary
<br />< I;;l <l.l
<br />:.. Proposed Land Building Sewer Building Sewer
<br />;::J,s <:.I Proposed Land Use
<br /><~ < Use Square Flow Square Flow'
<br /> Footage . (GPD) Footage (GPD)
<br />1 14.59 Medical Office 381,000 52,241 Office 175,000 24,500
<br /> Housing (29 TH) 34,800 7,995 Housing (60 TH) 72,000 16,560
<br /> Housing (120 CA) 96,000 6,720
<br />2 21.03 Hospital 549,640 109,928 Housing (360 CA) 288,000 21,060
<br /> Housing (lOI-CA) 80,800 6,057
<br />3 8.28 . Medical Office 270,508 37,060 Retail 151,800 20,823
<br />4 14.36 Service Mix 240,000 . . 39,940 Retail/Office/Restaunmt 225,913 35,060
<br />5 5.85 Office 140,154 19,201 Housing (82 TH) 98,400 22,632
<br />8 7.81 Housing (78 TH) 93,600 21,399 Housing(l08 TH) 129,600 29,808
<br /> 8.08 ROW/Green Space - - ROW/Green Space - -
<br /> (10 acres)
<br />Total 80.00 1,790,502 293,821 1,236,713 177,163
<br />
<br />The May 2001 AUAR anticipated construction of approximately 1,000 feet of 8-inch sanitary sewer line.
<br />The AUAR stated that all sanitary sewer facilities flow into an existing Metropolitan Council
<br />Environmental Services (MCES) interceptor, which then discharges to the Metro Sewage Treatment plant
<br />in St. Paul. The AUAR further stated that no capacity improvements would be required at the Metro
<br />Plant or with interceptor sewer facilities as a result of the proposed project.
<br />
<br />As identified in the table above, the anticipated sanitary sewer flows for the Rottlund Proposal are less
<br />than the AUAR anticipated flows and therefore, adequate capacity also exists for the Rottlund Proposal.
<br />
<br />Water Adequacy
<br />The May 2001 AUAR states that the development would be served by the existing municipal water
<br />system and that no wells were anticipated. The AUAR anticipated construction of approximately 3,000
<br />feet of 8-inch watermain and approximately 2,000 feet of 12-inch watermain; the Rottlund Proposal
<br />. anticipates use of similar lengths and sizes of public waterinain. Although a water use computation was
<br />not identified in the 2001 AUAR, industry standards anticipate that 70% to 80% of a community's
<br />domestic water use will return as wastewater. Therefore, as identified in the sanitary flows above, the
<br />
|