My WebLink
|
Help
|
About
|
Sign Out
Home
pf_02823
Roseville
>
Planning Files
>
Old Numbering System (pre-2007)
>
PF2000 - PF2999
>
2800
>
pf_02823
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/17/2007 12:13:48 PM
Creation date
12/8/2004 1:20:07 PM
Metadata
Fields
Template:
Planning Files
Planning Files - Planning File #
2823
Planning Files - Type
Division of Land
Address
350 OWASSO BLVD S
Applicant
TSCHIDA, FRANK
Status
APPROVED
PIN
012923130090
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
215
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />j <br />J <br />j <br />J <br />] <br />J <br />1 <br />J <br />J <br />I <br />J <br />J <br />J <br />] <br />j <br />J <br />J <br />1 <br /> <br />Curb Stop and box shaH be for copper service pipe inlet and outlet and boxes shall be <br />approved exten~ion service boxes of a uniform make. Inside diameter of upper section <br />shall be standard for curb stop with which it is to be used. <br /> <br />Curb stops shall be Mueller MK 11 H-I5I50, oriseal curb valves, or equal. All threads <br />shall conform to the requirements of A WW A C800. <br />I <br />Curb boxes sha!l be Mueller M 10300 through 1" and H-10836 for 1 1/2" and 2" or <br />equal, with foot piece and equipped with stationary rod equal to Mueller No. 84274, <br />A.Y. McDonald 5671. All boxes shall be adjustable up and down for seven and a half <br />feet of cover. <br /> <br />Curb boxes shall be gray iron castings confonning to the requirements of ASTM A 48 <br />for Class 20 or higher tensile strength. <br /> <br />Each curb box and curb stop shall be permanently and plainly marked with the name or <br />trademark of the manufacturer. <br />I <br />302.206 AIR RELIEF VAL VB AND VAL VB MANHOLE <br /> <br />Air relief valve and manhole shall be installed as shown on the plans. <br /> <br />Valves larger tnan 12 inches in diametershall be placed in manholes. Manholes shall <br />meet the requirements of the Special Details in the plans and the requirements specified <br />in the Storm Sewer. Specifications of Section 500. Manhole rrames and covers shall be <br />equal to Neenah R-1733 with "WATER DEPARTMENT II stamped on the cover. <br /> <br />302.300 INSULATION <br /> <br />Insulation shall be equal to Dow Chemical Company STYROFOAM III brand plastic <br />foam. installed in accordance with the manufacturer's recommendations and at a <br />minimum of 4" total thickness. <br /> <br />302.400 GASKETS <br /> <br />Rubber Gaskets for mechanical joint and push-on joint shall confonn to ASA A2I.II <br />and shall be designed and manufact\1red to exact dimensions to 'assure a liquid tight joint. <br /> <br />302.500 ELECTRICAL 'BONDING OF JOINTS <br /> <br />Each joint on cast iron pipe, valves, hydrants or fittings, either "push-on" or mechanical <br />joint type shall be electrically bonded with an external copper jumper capable of carrying <br />500 amps. of current for an extended period of time to provide integral electric thawing <br />capabilities. . <br /> <br />These copper jumpers can be either shop or field applied in accordance with these <br />specifications. For field applied copper jumpers, either the "Burndy- Thermoweld" as <br /> <br />300-5 <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.