Laserfiche WebLink
<br />Community Development Department <br />651-490-2279 . fax: 651-490-2931 <br /> <br />· The DRC also concludes that the fence proposed adjacent the drive lane on the west side <br />of the parking lot (adjacent the residential homes) meets the screening requirement. <br /> <br />· Section 1 006.02F, Off-Street Parking: The ORC has reviewed the submitted site plan <br />that slightly modifies the parking lot on the east and south side of Har Mar Mall and the <br />submitted landscape plan that screens the parking lot from the adjacent residential <br />district. The DRC concludes that most of the existing and previously approved off-street <br />parking is within 300 feet of a residential district, thus screening of this parking is <br />necessary, The ORC has determined that the proposed landscape screening appears to <br />meet the purpose and intent of this requirement. However, a final inspection will be <br />necessary to determine whether additional plantings are necessary to be consistent with <br />the 90% year round opacity requirement. <br /> <br />· Section 1006,020, Off-Street Loading: The ORC has determined that the existing docks <br />meet the loading and unloading requirements of the Code, Further, the ORC has <br />reviewed the submitted landscape plan including the fence details for the eastern buffer <br />strip and concludes that the proposed fence meets the requirements of the Code and that <br />the proposed landscaping meets the purpose and intent of the Code, However, a final <br />inspection will be necessary to determine whether additional plantings are necessary to <br />be consistent with the 90% year round opacity requirement. <br /> <br />· Section 1006.02H, Maintenance Activities: Though not specifically addressed, the ORC <br />concludes that the movement of sweeping vehicles, garbage trucks, maintenance trucks, <br />shopping carts, and other service vehicles are prohibited within 300 feet of the adjacent <br />(east, south, west) residential district between the hours of 10:00 p,m, and 7:00 a,m, <br /> <br />· The ORC has reviewed the submitted snow removal plan and accepts the plan as <br />consistent with the Code requirement and will keep the plan on file for future reference, <br /> <br />· Section 1006.021, Equipment Restrictions: Though not specifically identified on the <br />submitted plans, all roof top mechanical units within 300 feet of a residential area must <br />be completely screened as viewed from a point five feet above the first floor of adjacent <br />residences, Upon submittal of the interior remodeling plans, the DRC will review the <br />HV AC plans and make it detennination of compliance with the Code, <br /> <br />· Section 1006.02J, Lighting: The ORC has reviewed the parking light lighting plan and <br />the associated photometric plan and has detennined that the pole heights and foot <br />candles indicated meet both this Code and Section 1010,12, However, the plans do not <br />specify luminaire design, which must be either a recessed or flush mounted light source. <br />The ORC has determined that all 40 foot tall poles appear to be screened appropriately, <br />