My WebLink
|
Help
|
About
|
Sign Out
Home
pf_03614
Roseville
>
Planning Files
>
Old Numbering System (pre-2007)
>
PF3000 - PF3801
>
3600
>
pf_03614
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/17/2007 2:38:09 PM
Creation date
6/6/2006 3:23:37 PM
Metadata
Fields
Template:
Planning Files
Planning Files - Planning File #
3614
Planning Files - Type
Planning-Other
Status
Non-Active
Additional Information
Secure Computing
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
100
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br /> <br />annunciators, strobes and other warning devices; <br /> <br />17) All code required general exhaust requirements will be provided; <br /> <br />18} Landlord will meet all ADA requirements; <br /> <br />19}A Certificate of Occupancy will be obtained by landlord. <br /> <br />Ceiiinos <br />Landlord shall provide ceiling grid and it must be completed and <br />laser-leveled and capable of receiving 2'0" x 2'0" exposed t-bar <br />acoustic tile installation. Ceiling tile must be 2' x 2' lay-in tegular <br />edge regressed, noncombustible mineral, foil-backed, fissured, <br />acoustical tile, with a minimum thickness of 3/4", an NRC rating of <br />.55 to .65, an STC rating of 35 to 39, and a light reflectance rating of <br />LRl and shall be stocked on the floor of the Tenant space. Tenant's <br />contractor shall install ceiling tile at Tenant's cost. Alternative lay-in <br />ceiling systems will be considered provided they meet the above <br />standards. <br /> <br />Acoustical Attenuation <br />Acoustical attenuation will be designed within walls separating <br />elevators, toilet rooms, fan rooms, and switchgear from occupied <br />Tenant spaces. The system design criteria for ambient noise level in <br />Tenant's space, when unoccupied, shall meet NC35 standards <br />when all building systems are operating and standard floor and <br />ceiling finishes are installed. <br /> <br />Mechanical Construction <br />Heatinq, Ventilation and Air-Conditioninq ("HV AC") <br />Landlord will furnish and install an HV AC system to meet local <br />building codes to meet an occupant load of 1 person per 125 <br />square feet. Landlord will provide HV AC system completed through <br />and including the V A V or heat pump devices to meet Secure <br />Computing's final plan and the following: <br /> <br />a) The system, including exhaust fans, will be designed to conform to <br />Tenant's plans and to operate so that sound transmission levels do <br />not exceed NC35 as required by code in common areas. <br /> <br />b) The system will be designed with no more than 50 lineal feet per <br />
The URL can be used to link to this page
Your browser does not support the video tag.