1 <br />1 <br />' DIVISION 3 <br />CONCRETE <br />03300 - CAST -IN -PLACE CONCRETE <br />2. Keep subgrade free of frost before concrete placing begins. If <br />temperature inside a building where concrete is to be laced <br />is <br />freezing, raise temperature and maintain above 500 Ton enough <br />remove all frost from subgrade. 9 gh to <br />3. Where slab is placed directly on earth, keep subgrade moist at time <br />concreting. Allow no free water standing on subgrade nor an mudof <br />soft spots when concrete is placed. Y y or <br />4. Where noted on the drawings, at all floor drains, clean <br />o and <br />similar items in slab -on -grade, box out a hole 2' square insslabs, <br />allowing drains to be set after <br />floor has been installed. <br />B. Edge forms and screeds: <br />I. Set edge g forms and intermediate screed strips accurately to produce <br />designated elevati^ns and contours of finished surface sufficiently <br />strong to support vibrating screeds or roller pipe screeds, if nature <br />of finish specified requires use of such equipment. Align concrete <br />surfaces to contours of screed strips by use of strike -off templates <br />or approved compacting type screeds. <br />C. Placemen <br />t: <br />I. Carefully coordinate mixing and placing with finishing. Do not p lace <br />conrete on subgrade or forms more rapidly than it can be spread <br />straight -edges, and darbled or bull floated. ' <br />op <br />before bleeding water has an opportunity to collectrontsurfaceerations <br />2. To obtain good surfaces and avoid cold joints, plan size of finfshin <br />crews with due regard for efforts of concrete temperature and g <br />atmospheric conditions on rate of hardening of concrete. If <br />construction joints become necessary, construct as required under <br />Joints and Embedded Items. <br />D. Jointing: Locate joints in slabs on <br />grade <br />are permitted. Other methods may be used atsthe ddiscretion aofcut joints <br />Contractor. Pour floor slabs in "strip" or "Checkerboard" panels in sizes <br />approved by Architect. Pattern shall be not larger than 30 x 30 grid lines). Provide isolation control and construction joints of type <br />and size indicated and place as shown. Isolate walls and columns from <br />floor. <br />E. Consolidation: Thoroughly consolidate concrete in slabs. Use internal <br />vibration along bulkheads of slabs on grade. Obtain consolidation of <br />slabs with vibrating screeds, roller pipe screeds, internal vibrators, or <br />other approved means. <br />F. Finish floor slabs as hereinafter specified under Article 13. <br />5264 <br />SECTION 03300 - 7 <br />