I <br />DIVISION 4 <br />MASONRY <br />04220 - MASONRY WORK <br />P. Install where specified. Where flashing is to be laid on or against <br />masonry, surface of masonry shall besmooth and free from projections which <br />might puncture flashing material. Provide well lapped joints (6) with <br />adhesive to form well sealed joints. Make laps in direction of water <br />flow. Install flashing to properly drain cavity or effectively prevent <br />moisture from steel. At head joints (on top of flashing) place rope wicks <br />24" o.c. Cut off flashing so it does not extend to brick face. <br />Q. No masonry work shall be permitted in below freezing temperatures unless <br />acceptable means are provided for heating materials and protecting <br />completed work to temperatures above 400F. <br />R. All cementitious and masonry materials shall be stored and covered to <br />protect these materials from moisture. Completed work shall also be <br />protected with waterproof covering. <br />6. REINFORCED HOLLOW MASONRY WALLS <br />A. All reinforced hollow masonry walls shall be constructed as follows: <br />1. All reinforced hollow unit masonry shall be built to preserve the <br />unobstructed vertical continuity of the cells to be filled. hails and <br />cross webs forming such cells to be filled shall be full -bedded in <br />mortar to prevent leakage of grout. All head (or end) ,points shall be <br />solidly filled with mortar for a distance in from the face of the wall <br />or unit not less than the thickness of the longitudinal face shells. <br />Bond shall be provided by lapping units in successive vertical courses <br />or by equivalent mechanical anchorage. <br />2. Vertical cells to be filled shall have vertical alignment sufficient <br />to maintain a clear, unobstructed continuous vertical cell measuring <br />not less than 2" x 3". <br />3. Cleanout openings shall be provided at the bottom of all cells to be <br />gilled at each pour of grout where such grout pour is in excess of 4' <br />high. Any overhanging mortar or other obstruction or debris shall be <br />removed from the insides of such cell walls. the cleanouts shallb e <br />sealed before grouting after inspection. <br />4. Vertical reinforcement shall be held in position at top and bottom and <br />at intervals, not exceeding 192 dia. of the reinforcement. <br />�' I <br />5264 <br />5. All cells containing reinforcement shall be filled solidly with <br />grout, Grout shall be poured in lifts of 8' maximum height. All <br />grout shall be consolidated at time of pouring or vibrating and then <br />reconsolidated by again puddling later, before plasticity is lost. <br />SECTION 04220 - 5 <br />1 <br />