Laserfiche WebLink
<br />77 Headquarters facility are located on the side or the rear of the building. Specifically, there are three <br />78 overhead doors on the east side of the building, two overhead doors on the south side, and a set of <br />79 overhead doors on the west side of the building, all serving ingress and egress for general parking, a <br />80 wash bay, large evidence storage, and/or to access a bay for training purposes. Lastly, there is an <br />81 overhead door on the north side of the building facing Highway 36, however it cannot be seen due to the <br />82 required screen wall associated with the trash and recycling for the facility. Given the use of the <br />83 building, the proposal for overhead doors seems reasonable. <br />84 <br />85 E. Frontage Requirement: A development must utilize one or more of the three options below for <br />86 placement of buildings and parking relative to the primary street: <br />87 3. At least 70% of the street frontage shall be occupied by building facades placed within 85 feet <br />88 of the front lot line. Only two rows of parking and a drive aisle may be placed within this setback <br />89 area. <br />90 <br />91 The purpose of this Design Standard and the three setbacks associated with the Frontage requirement <br />92 is to encourage sites to be developed near the public realm and/or be pedestrian-friendly by building <br />93 forward and locating parking to the side and rear of the property. Hence, the maximum requirement of <br />94 an 85-foot building setback, allowing two rows of parking between the street and building. The State <br />95 Patrol Headquarters building is situated in a similar location to that of the former State Farm Insurance <br />96 building, which is to have a visual presence on Highway 36. Beyond highway visibility desires, the State <br />97 Patrol facility requires security features that limit the public’s ability to access the building. These <br />98 reasons negate the need for the building to be nearer the public realm. These factors effectively result <br />99 in the State Patrol headquarters building occupying approximately 628 feet of frontage on Commerce <br />100 Street, or 39%, when the strict application of this Design Standard would require 1,139 feet of the <br />101 building to be located within 85 feet of the front lot line in order to meet the 70% frontage <br />102 standard. Further, the proposed site plan illustrates a building setback ranging from 117 feet to 170 feet <br />103 from Commerce Street, containing up to four rows of parking with two drive lanes in-between. Lastly, <br />104 there is an accessory building proposed near the southeast corner of the property adjacent to the <br />105 ingress/egress of Highway 36 and Commerce Street. The accessory building will house a couple of <br />106 State Patrol trailers and the magazine unit for explosives storage. Given the use of the building, the <br />107 proposed building placement and its occupied frontage seem reasonable. <br />108 <br />109 3. Fences in front yards shall not exceed 4 feet in height. Notwithstanding this limitation, fences in <br />110 front yards which are adjacent to the side or rear yards of abutting lots may be as tall at 6.5 feet. <br />111 <br />112 “front yard” is deemed to be Commerce Street. The proposal by the State Patrol is for a fully secure <br />113 facility that includes 8-foot-tall perimeter fencing for each parcel and 8-foot-tall security-controlled gate <br />114 access for employees. Public access during time-appropriate periods will be provided via electronically <br />115 monitored access. As such, fencing is proposed at a height 4 feet taller than this standard permits in the <br />116 front yard and 1-1/2 feet taller than this standard permits everywhere else. Given the use of the building, <br />117 the fencing proposed seems reasonable. <br />118 <br />119 To summarize the above analysis, and in order to permit the items staff has highlighted above, the City <br />120 Council must approve the proposed site plan via the “Special or object-oriented buildings” provision in <br />121 Section 1007.02.8. Staff finds the uniquely designed building and use to meet the purpose and intent of <br />122 this zoning provision and would recommend approval. <br />123 <br />124 Comprehensive Land Use Plan Map Change <br />125 Applicant-initiated Comprehensive Plan and Official Zoning Map changes undergo the same open house <br />126 and public hearing process as City-initiated map changes. Comprehensive Land Use Plan Map <br />127 amendments also require the City Council to approve with an affirmative vote of at least 4/5ths of the <br />128 City Council’s total membership. <br />129 <br />130 As stewards of the Comprehensive Plan, staff have been advancing specific goals, policies, and <br />131 strategies contained within the Land Use Chapter of the Plan since its last update in 2019. Similarly, <br />132 when developments come forward seeking guidance concerning the Comprehensive Plan, staff work <br />Page 3 of 5 <br />Qbhf!37!pg!33: <br /> <br />