My WebLink
|
Help
|
About
|
Sign Out
Home
ord_100
Roseville
>
City Council
>
City Council Ordinances
>
0100
>
ord_100
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/17/2007 9:03:40 AM
Creation date
4/22/2005 12:47:51 PM
Metadata
Fields
Template:
Roseville City Council
Document Type
Council Ordinances
Ordinance #
100
Ordinance Title
An ordinance providing for all matters concerning, regulating or affecting the construction, alteration, regulation, repair and inspection of all buildings, walks, structures erected or to be erected in the Village of Roseville for the protection of
Ordinance Summary
An ordinance providing for all matters concerning, regulating or affecting the construction, alteration, regulation, repair and inspection of all buildings, walks, structures erected or to be erected in the Village of Roseville for the protection of
Ordinance Date Passed
5/27/1948
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />4-6. In all <br />taine water, <br />the moisture <br /> <br />,.';' 007 <br />cases where basements are constructed in ground whféh' con- <br />suitable provisions shall be made to properly carry off <br />from such soil. <br /> <br />) <br /> <br />4-7. At least two (2) foundation wall, vents having a total effective <br />area of one square foot for each fifteen lineal feet of exterior wall <br />shall be installed in each basementless space. Vents shall be co~ered <br />with 1/8" mesh non-corrodible ecreem1ng. Venting not required when <br />basementless space is open to a ventilated basement. <br /> <br />4-8. Basement or cellar floor slabs shall not be less than three (3) <br />inch concrete if finished monolithic; otherwise three (3) inch concrete <br />and one (1) inch topping. <br /> <br />4-9. Wood posts in basements shall bear on a cement base which shall <br />extend not less than four (4) inches above the finished floor and shall <br />rest on top of the footing. Top of posts shall be 8e~urely fastened to <br />the girders. <br /> <br />4-10. Beam filling will be required around all exterior openings in <br />masonry veneer walls and all intersections of wood and masonry. <br /> <br />4-11. Basements shall be provided with means of light and ventilation <br />of not less than two per cent (2,%) of the floor areâ. ' <br /> <br />4-12. An access opening of not less than lß"x24", or its equivalent, <br />shall be provided to each basementless space under wood or metal floor <br />construction. ' <br /> <br />4-13. The walls of chimneys used for stoves, ranges, fireplaces, heat- <br />ing furnaces or other heating appliances regar~less of the type of fuel <br />to be used shall be built of brick, concrete, stone or hollow tile of <br />such thickness and construction as is hereafter specified. <br /> <br />4-14. All chimneys irrespective of which materials the walls are built <br />shall be lined with fire clay flue lining or with fire brick. T~e lining <br />shall be made for the purpose and adapted to withstand the temperatures <br />and the resultant gases. <br /> <br />4-15. Solid brick or concrete chimneys shall not be less than four (4) <br />inches thick exclusive of flue lining. A standard size brick laid flat- <br />wise shall be deemed to fulfill this requirement for brick chimn~YB. <br /> <br />4-16. Stone and hollow tile chimneys shall have a minimum thickness of <br />eight (8) inches. <br /> <br />4-17. Hollow tile may be used in the construction of a chimney only <br />where said chimney is part of an exterior tile wall. <br /> <br />4-18. The foundation of an exterior chimney shall start below the <br />frost line. <br /> <br />4-19. In frame buildings the chimney shall always be built from the <br />ground up or rest upon the basement walls. <br />