Furnish and install a new e�aust fan for toilet room 1131 as called out in RFI # 150. The <br />e�stingfan in this roof did not work and by code needed to be replaced. Add $497 <br />Add for NAC to install the gas line piping for the temporary gas heaters that were used this <br />winter. There was a cost for this change built into the McGough general conditions. <br />Add $3,636 <br />Add to bring the irrigation stub-out to the outside of the building. The drawings showed this <br />irrigation connection at the inside of the building that did not work for the irrigation <br />contractor. Half of this cost has been charged back to the irrigation contractor. Add $1,448 <br />Add to re-route and re-connect the sanitary line in the lower level to service the upper level <br />toilet rooms. The existing sanitary line was not shown in drawings and assumed to have been <br />removed in earlier remodel and had to be removed since the pipe was in the middle of a new <br />office. Add $679 <br />Install a new wa11 hydrant and in the lower level of the PS building. This wa11 hydrantwas <br />not shown on the drawings to be saved or removed. The City decided it needed to be kept so <br />a new wa11 hydrant was installed to replace this old leaking hydrant. Add $294 <br />Deduct for work that was completed by A& P for the plumbers on 12/22/03 and 12/23/03. <br />This work included repairing block walls in Room 1131 for the plumbers. (Deduct $1,504) <br />� • � i � � i � _ � � I ' �� <br />Add for unexpected floor prep�ration in the men's locker room in the PW building. <br />Add $1,027 <br />Add for unexpected floor preparation in the women's locker room in the PW building. Add <br />$496 <br />Add for floor preparation associated with the expansion j oint at the first floor of the PS <br />building. This costwill be chargedto Right-Way Caulking. Add $526 <br />1� � :�� i� :�� ' I <br />Add two (2) new roof drains per PR #20. These drains were added after the roof had been <br />installed. Add $900 <br />Add for installing two (2) new plumbing vents through the roof after the roof had been <br />complete. These vents were added per the Minnesota Department of Health review. <br />Add $450 <br />Add to patch around added roof penetrations because of the increased gas pressure into the <br />PS building per PR #41. Add �680 <br />Add for Da1co to furnish and install additional2 x 4 blocking at the PW building to get the <br />parapet flashing on the old building to line up with the parapet flashing on the new building. <br />Add $380 <br />